https://supportforums.cisco.com/message/3198115#3198115

 

UCCX 8 and the request to the cisco CTI server timed out

we upgraded from UCCX 7 to 8 and CUCM 7 to 8. For a week everything wokred fine but all of a sudden agents could no longer login into their phone. they got the following error: The Request to the Cisco CTI server timed out. try again.

 

they got an error with the CAD as well, however, the work around for that was to

Navigate to:

C:\Program Files\Cisco\Desktop\config

Open PhoneDev.cfg file via notepad and add the following to the file:

[ReqTimeout]
Milliseconds=1200000

Save this file and then log into the agent desktop.

 

I opened a TAC case gathered traces and they found one case that has experienced samed thing. it has been escalated to BE Unit.

 

any help would be appreciated.

Average Rating: 0 (0 Votes)

 

anubhati

 

189 posts since
Jul 17, 2006

Oct 8, 2010 6:12 PM (in response to kiru)

Re: UCCX 8 and the request to the cisco CTI server timed out

Hi

 

When CAD agents login, UCCX sends the CAD info to CUCM for authentication. If CUCM is integrated with AD it further forwards the info to the first DC. Once the DC authenticates the info ack is sent back to UCCX and then CAD gets logged in. By default UCCX has a time out window of 10 seconds and if the ack does not come by, within this 10 seconds CAD agents fail to login and you see a time out issue.

 

In your case, Is CUCM integrated with AD through LDAP ? If yes check if there is no communication delay between CUCM and DC. Also check the DC event logs to confirm if those servers are working properly or not.

 

Hope this helps isolating the issue

 

Anuj Bhatia

===================

Average Rating: 0 (0 Votes)

 

Jos De Bruin

 

3 posts since
Aug 6, 2003

Dec 2, 2011 3:51 AM (in response to anubhati)

Re: UCCX 8 and the request to the cisco CTI server timed out

Hi,

 

I think your problem should be solved, but for the record :

 

Our solution was to restart the AXL on the CUCM.

It looked like authentication went wrong.

By changing the parameter suggested for CAD we came to this conclusion, because the CAD agent 'worked' slowly and the IPPA did not.

 

Kind Regards,

 

Jos de Bruin